Product Line
  
RF Product Type
Cable Assembly
1.6 /5.6
7/16
Adapter - Kit
Adapter
BNC
F
FME (Antenna)
MCX
MMCX
Mini - UHF
N
R/P Adapter
R/P BNC
R/P N
R/P SMA
R/P TNC
SMA
SMB
SMC
SSMB
STP
TNC
UHF
Application
RF Antenna
WLAN
Mobil Communication
Communication Satellites Stations
Defense Industry
Brand
Arthur-yang
A to Z
 
 

TNC SERIES ( 50ohm 0-11 GHz / 75 Ohm 0-1GHz)

 

ZOOM

Name :TNC SERIES ( 50ohm 0-11 GHz / 75 Ohm 0-1GHz)
Item No. : 24- TNC Connector

Add to Inquiry Cart

TNC SERIES ( 50ohm 0-11 GHz / 75 ohm 0-1GHz)

TNC series features screw threads for mating. Threaded coupling interface ensures connector will not de-couple in vibration-intensive applications.
Our TNC connectors are with constant 50Ω and 75 Ω impedances, and operate from 0 - 11 GHz. TNC connectors are primarily used to antennas, base station, cellular, network, radar, telecom…etc.
Reverse Polarity TNC is also available.

TNC SERIES ( 50ohm 0-11 GHz / 75 ohm 0-2GHz)
 

  TNC-PLUG   TNC-JACK
  Min Max   Min Max
A 11.18   A 9.60 9.70
B  Flared to Meet Good Electrical Contact B 8.79 9.04
C 4.83 - C 8.31 8.46
D 1.32 1.37 D 8.10 8.15
E 5.33 5.84 E - 4.72
F 0.15 0.46 F 1.73 2.24
G 5.28 5.79 G 8.31 8.51
H 0.08 1.02 H 4.75 -
J 2.06 2.21 J 4.72 5.23
K 1.98 - K - 0.15
M - 1.98 L 4.95 -
N 1.60 - M 2.06 2.21
P 3.96 - N - 6.50
R - 0.64 P 4.78 5.28
      R 10.52 -
      S 0.38 0.76

 

NOTE 1 : I.D. TO MEET VSWR AND CONTACT RESISTANCE

WHEN MATED WITH 1.32/1.37 MM DIA. PIN.



Material

Part Name

Material

Finish

Bodies

Brass

Nickel, Mirraloy…
( per requirement)


Center Contacts

Male: Brass


Gold, Nickel…
(per requirement)

Female: Brass, Phosphor Bronze,
Beryllium Copper

Insulators

Teflon, Delrin, PBT

None

Gaskets

Rubber, Silicone Rubber

None

Ferrules

Annealed copper

Same as Body

Electrical Data

Impedance

50Ω

75Ω

Frequency Range

0~11 GHz

0-1 GHz

RF-Leakage
–connector for flexible cables
–connector for semi-rigid cables

( 60 dB)

( 60 dB)

Dielectric Withstanding Voltage
( at sea level )

1.5K Vrms, 50Hz
(depending on cable)

1.5K Vrms, 50 Hz
(depending on cable)

Working Voltage (at sea level)

500 Vrms,50Hz

500 Vrms,50Hz

500 Vrms, 50Hz
(depending on cable)

500 Vrms, 50Hz
(depending on cable)

Insulation resistance

5103 Ω

5103 Ω

Contact resistance

- center contact

3 MΩ ( 1.5MΩ)

3 MΩ ( 1.5 MΩ)

- outer contact

2 MΩ ( 1 MΩ)

2 MΩ ( 1 MΩ)


VSWR

Straight:1.3 max

Straight:1.3 max

Right Angle:1.5 max

Right Angle:1.5 max

Mechanical

Engagement Force

2 in-lbs. max

Disengagement Force

2 in-lbs. max

Coupling retention force (nut)

100 lbs. min.

Coupling Proof Torque (nut)

15 in-lbs. min

Contact captivation

6 lbs. min

Durability (Mating)

500 cycles min
(for Beryllium Copper female contact only)

Environmental Data

Temperature range

-65 ~ 165

Thermal shock

MIL-STD-202, Method 107, Condition B

Moisture resistance

MIL-STD-202, Method 106

Corrosion

Saltspray test acc. To MIL-STD-202,
Method 101, Conditions B

Vibration

MIL-STD-202, Method 204, Condition B

Shock

MIL-STD-202, Method 213, Condition G