Product Line
  
RF Product Type
Cable Assembly
1.6 /5.6
7/16
Adapter - Kit
Adapter
BNC
F
FME (Antenna)
MCX
MMCX
Mini - UHF
N
R/P Adapter
R/P BNC
R/P N
R/P SMA
R/P TNC
SMA
SMB
SMC
SSMB
STP
TNC
UHF
Application
RF Antenna
WLAN
Mobil Communication
Communication Satellites Stations
Defense Industry
Brand
Arthur-yang
A to Z
 
 

MCX SERIES ( 50 Ohm 0-6 GHz)

 

ZOOM

Name :MCX SERIES ( 50 Ohm 0-6 GHz)
Item No. : 11- MCX Connector

 

Add to Inquiry Cart

MCX SERIES ( 50 ohm 0-6 GHz)

MCX connector, featuring subminiature and snap-on coupling mechanism, comes with identical inner contact and insulator dimensions as the SMB while being smaller by 30%. It is an ideal option when weight and physical space are major concerns.

MCX SERIES


  MCX-PLUG   MCX-JACK
  Min Max   Min Max
A 3.72 3.80 A 3.60 3.70
B 2.49 2.59 B 2.80 -
C 0.48 0.53 C 3.75 3.85
D 4.15 - D 4.00 4.12
E 0.70 0.75 E 0.75 0.85
F 2.80 3.20 F 2.30 2.80
G 0.95 0.95 G 0.95 0.95
H - 0.30 H 3.42 3.48
I 2.00 2.07 I 1.80 1.97

K

2.80

3.20

K

2.60

2.80

NOTE : I.D.TO MEET VSWR AND CONTACT RESISTANCE

WHEN MATED WITH MM DIA.PIN.



 

Material

Part Name

Material

Finish

Bodies

Brass

Gold..(perrequirement)

Center Contacts

Male: Brass

 

Female:
Phosphor Bronze

Gold..(perrequirement)

Beryllium Copper

 

Insulators

Teflon

None

Outer Contacts of male

Beryllium Copper

Gold

Crimp Ferrules

Annealed Copper

Same as Body

Electrical Data

Impedance

50Ω

Frequency Range

0 – 6 GHz

Dielectric Withstanding voltage

1000 Vrms, 50 Hz at sea level

Working Voltage
(at sea level)

335 Vrms, 50Hz

Insulation Resistance

1000 MΩ

Contact Resistance

 

- center contact

5 mΩ

- outer contact

2.5 mΩ


VSWR

Straight: 1.3. max

Right Angle: 1.5. max

Mechanical & Environmental 

Contact Retention

4 lbs, min

Durability (Mating)

500 cycles min
(for Beryllium Copper female contact only)

Temperature Range

-65 ~ 165

Engagement Force

3.4 lbs. max

Disengagement Force

4.5 lbs.. max

Salt Spray

MIL-STD-202 Method 101 Test Cond.B

Temperature Cycling

MIL-STD-1344 Method 1003 Test Cond.A

Vibration